Revolutionize Healthcare with The Ultimate Portable Digital X-ray Machine

Still deciding? Get samples of $ !
Request Sample

Product Description

Basic Information

Model NO.DR500A
CertificationCE, FDA
GroupMiddle-aged and Old
Gross Weight75kgs
Output Power5.3kw
Input Voltage220VAC, ±10%, 50Hz
Inverter Frequency100kHz, ±5%
Kv Range40kv ~ 125kv
Ms Range1ms ~ 4000 Ms
Mas Range0.1mas ~ 200mas
X-ray Tube Voltage125kv
Nominal Focal Spot0.6mm (Small Focus) / 1.8mm (Large Focus)
Effective Area427mm × 427mm
Trigger ModeAed (Optional) / Software / Prep
Specification120 * 140 * 50CM
OriginChina

Product Description

New Standard for Portable X-ray Radiography Machines

Medical Imaging Equipment - RD-500A Configuration

Portable X-ray Machine
Component Performance Parameters
High-voltage Generator Output: 5.3kW; Input: 220VAC; Frequency: 100kHz; kV: 40-125kV; mAs: 0.1-200mAs
X-ray Tube Voltage: 125KV; Focal Spot: 0.6mm/1.8mm; Target Angle: 15°; Target: Tungsten
Collimator Inherent Filtration: 1mm AL; Max Radiation Field: 450mm×450mm
Flat Panel Detector a-Si TFT; CsI Scintillator; Array: 3072×3072; Pixel: 139um; Area: 427x427mm
Imaging Speed Preview Time: 3s; Imaging Time: 5s; Resolution: 3.6 lp/mm; AD Conversion: 16 bit
Mobile Machine Height Range: 1090mm-2120mm; Adjustment: 920mm-1950mm; Rotation: 360°
Device Detail
X-ray View 1
X-ray View 2
X-ray View 3
X-ray View 4
X-ray View 5
X-ray View 6

Manufacturing Excellence

A well-known domestic medical device manufacturer and service provider, recognized as a national high-tech and technology-based enterprise. Dedicated to the innovative development and manufacture of ultrasound imaging, digital electrocardiograph, and digital radiology imaging products.

With more than 50 models in 5 major categories, including color Doppler ultrasound systems, digital electrocardiogram machines, patient monitors, and digital radiography. The manufacturing process follows strict quality systems including ISO13485 and European CE certification.

Workshop 1
Workshop 2
Facility Overview

Frequently Asked Questions

What is the power output of the DR500A?
The system features a high-voltage generator with a robust output power of 5.3kW and an inverter frequency of 100kHz.
What is the adjustable height range for the mobile unit?
The machine height range is between 1090mm and 2120mm, with a specific adjustment range for operation between 920mm and 1950mm.
Does the Flat Panel Detector support fast imaging?
Yes, it provides a quick preview time of just 3 seconds and a full imaging time of 5 seconds, ensuring high efficiency in clinical workflows.
What are the kV and mAs ranges available?
The equipment offers a kV range of 40kV to 125kV and an mAs range of 0.1mAs to 200mAs, suitable for various diagnostic needs.
Is the system certified for medical use?
The product is fully compliant with international standards, holding both CE and FDA certifications.
What is the resolution of the detector?
The Flat Panel Detector features a pixel size of 139 um and a spatial resolution of 3.6 lp/mm with 16-bit AD conversion for high-quality imaging.

Related Products